Sticking coefficients of selenium and tellurium

in house research highlight
Project Summary: The sticking coefficients of thermally evaporated chalcogen elements selenium and tellurium were experimentally determined as a function of temperature. Their direct and quantitative determination provides important insights to comprehend and realistically model the growth kinetics of chalcogenide-based film growth.
A direct way to determine the ratio of chalcogenide elements sticking to a film surface is to measure the rate of mass accumulated, which was achieved by depositing selenium and tellurium on a quartz crystal microbalance held at different temperatures.
Pronounced reduction of the sticking coefficients by a factor of 4 in a very narrow temperature range of 20°C and 30°C around temperatures of 35°C and 115°C were found for selenium and tellurium, pointing towards the critical need of precise temperature control during chalcogenide film growth using molecular beam epitaxy. The results reveals that unlike tellurium, selenium is supplied in different chemical forms with different desorption characteristics.
CONTACT:

National Science Foundation

Division of Materials Research

2415 Eisenhower Avenue

Alexandria, VA 22314

Any opinions, findings and conclusions or recommendations expressed in this material are those of the author(s) and do not necessarily reflect the views of the National Science Foundation.
SOCIAL: